top of page
Validating Measurement Systems

The Measure Phase in the Six Sigma methodology is a critical stage where the current process performance is assessed and measured. One of the key components in this phase is validating measurement systems. The purpose of this validation is to ensure that the data collected are accurate and reliable, providing a solid foundation for the subsequent phases of the Six Sigma project.

Understanding Measurement System Analysis (MSA)

Measurement System Analysis (MSA) is a collection of techniques used to evaluate a measurement system. The focus is on the measuring equipment and the process of measurement itself. MSA assesses the precision and accuracy of the measurement system to determine if it is capable of providing useful data.

Key Concepts in MSA

  1. Accuracy: Refers to how close the measurements are to the actual value.

  2. Precision: Involves the consistency of the measurement results when repeated under unchanged conditions.

  3. Repeatability and Reproducibility (R&R): R&R study is a part of MSA that evaluates the variation in the measurements caused by the measurement system. 

Steps in Validating Measurement Systems

1. Define the Measurement System

Start by defining what is being measured and how it is being measured. This includes understanding the operational definition of the measurement and identifying the measurement tools and techniques used. 

2. Conduct a Gage R&R Study

Gage R&R study is the most common method used in MSA. It assesses whether the variation in the output of your measurement system is acceptable compared to the total variation in your process measurements.

  • Repeatability: Examines how consistent results are when the same operator measures the same item using the same device.

  • Reproducibility: Analyzes the variation in measurements when different operators use the same measuring device to measure the same item. 

3. Analyze the Measurement Data

Using statistical analysis, determine the level of measurement error. Tools like ANOVA (Analysis of Variance) can be employed to analyze the results of the Gage R&R study. The goal is to quantify how much of the total variation is due to the measurement system. 

4. Evaluate the Measurement System

Based on the analysis, determine if the measurement system is adequate. If the system's variability is high compared to the total process variability, improvements or changes to the measurement system may be necessary. 

5. Take Corrective Actions if Necessary

If the measurement system is found to be lacking, take corrective actions. This could involve calibrating the measurement instruments, training for operators, or even redesigning the measurement process. 

6. Document and Standardize

Once the measurement system is validated, document the process and standardize the measurement procedures. This ensures consistency in future measurements and provides a reference for ongoing process control. 

Best Practices in Measurement System Validation

  • Regular Calibration: Regularly calibrate measuring instruments to maintain accuracy.

  • Training: Ensure that all personnel involved in measurements are adequately trained.

  • Continuous Monitoring: Continuously monitor the measurement system for any deviations or changes over time. 

Conclusion

Validating the measurement system in the Measure Phase is crucial for the success of a Six Sigma project. A reliable measurement system not only contributes to the accuracy of the current project but also lays a strong foundation for the Analyze, Improve, and Control phases of the Six Sigma methodology. Remember, the goal of Six Sigma is to make data-driven decisions, and it starts with ensuring that your data is precise and accurate.

Curent Location

/412

Article

Rank:

Validating Measurement Systems

50

Section:

LSS_BoK_1.2 - The Fundamentals of Six Sigma

C) Measure Phase

Sub Section:

Previous article:

Next article:

bottom of page